News
-
What is the best cleaning solution for Laboratory Analisis Hplc Vials?
The content expressed in this article is What is the best cleaning solution for Laboratory Analisis Hplc Vials? please feel free to contact me. See how the polarity of your Laboratory Analisis Hplc Vial is. The usual cleaning method is: pour out the sample solution and soak it in the surfactant, that is, wash the spirit water, ultrasonic for more than 30min, so that it is washed 2-3 times repeatedly, then washed with tap water for 3 times, then cleaned and then used pure Wash water 1-2 times. If the sample is not easily soluble in water and soluble in organic solvents, it can be washed with ethanol for 2-3 times and then washed with tap water. The general idea is to wash with a solvent that is soluble. The above content is What is the best cleaning solution for Laboratory Analisis Hplc Vials? I hope it will help you!
2018 12/06
-
Can the autosampler vials be universal?
The content expressed in this article is Can the autosampler vials be universal? please feel free to contact me. Not quite the same. Gas chromatographic syringes generally require less injection, 0.2-1 ul is the most common injection volume, so its needles are generally used for 10-25 ul, and for easy injection, the needle tip is It is sharp. The liquid chromatography injection volume is generally larger, usually 0.5-20ul, so the volume of the needle is larger, generally 25-100UL, and the tip of the needle is flat, because the tip will scratch the stator . The above content is Can the autosampler vials be universal? I hope it will help you!
2018 12/06
-
How is the sample bottle filtered?
The content expressed in this article is How is the sample bottle filtered? please feel free to contact me. Inject the needle into the syringe chain, then remove the filter head (0.45, 0.25um) from the needle sleeve and discard the 4, 5 drops of the initial filtrate to remove the filtrate; Micro-injectors can also be put on, are the injection heads not all uniform? If it is not possible to seal with a sealing film. The above content is How is the sample bottle filtered? I hope it will help you!
2018 12/06
-
Why is GC Vial heated?
The content expressed in this article is Why is GC Vial heated? please feel free to contact me. Because the sample in GC Vial is incubated for a sufficient time to reach the gas-liquid equilibrium, the appropriate volume of gas can be volatilized for the sample to be drawn into the chromatogram. Otherwise, the amount of gas volatilized from the sample at normal temperature is small and not stable enough. It is not possible to determine at all. The above content is Why is GC Vial heated? I hope it will help you!
2018 12/06
-
What is the meaning of autosampler sample bottle number -1?
The content expressed in this article is What is the meaning of autosampler sample bottle number -1? please feel free to contact me. Just don't inject. If you choose a autosampler sample bottle, you must enter at least 1 ul. If the bottle is chosen to be -1, it is injected with 0ul and the method is run directly. The above content is What is the meaning of autosampler sample bottle number -1?I hope it will help you!
2018 12/06
-
Where is the 300ul injection bottle intubation?
The content expressed in this article is Where is the 300ul injection bottle intubation? please feel free to contact me. Quzhou Laibo Technology Co., Ltd. produces complete series of consumables for gas chromatography, high performance liquid chromatography and headspace analysis. Such as: 2mL jaw head bottle, Where is the 300ul injection bottle intubation,4-60mL storage bottle, gas phase jaw head bottle, 9mm short thread sample bottle, 8-425 thread sample bottle, threaded head bottle and other models of autosampler, chromatographic sample Bottles, septa, filters, glanders, chromatography filters and other accessories, such as professional production and processing companies, have a complete, scientific The above content is Where is the 300ul injection bottle intubation? I hope it will help you!
2018 12/06
-
Where is the Wide Opening 2ml Snap Glass Vial ?
The content expressed in this article is Where is the Wide Opening 2ml Snap Glass Vial ? please feel free to contact me. Quzhou Laibo Technology Co., Ltd. produces complete series of consumables for gas chromatography, high performance liquid chromatography and headspace analysis. Such as: Wide Opening 2ml Snap Glass Vial, 4-60mL storage bottle, gas phase jaw head bottle, 9mm short thread sample bottle, 8-425 thread sample bottle, threaded head bottle and other models of autosampler, chromatographic sample Bottles, septa, filters, glanders, chromatography filters and other accessories, such as professional production and processing companies, have a complete, scientific quality management system, welcome everyone to visit, guidance and business negotiations. The above content is Where is the Wide Opening 2ml Snap Glass Vial ? I hope it will help you!
2018 12/06
-
How is the hplc vials filtered?
The content expressed in this article is How is the hplc vials filtered? please feel free to contact me. Inject the needle into the syringe chain, then remove the filter head (0.45, 0.25um) from the needle sleeve and discard the 4, 5 drops of the initial filtrate to remove the filtrate; Micro-injectors can also be put on, are the injection heads not all uniform? If it is not possible to seal with a sealing film. The above content is How is the hplc vials filtered? I hope it will help you!
2018 12/06
-
How is the hplc vials filtered?
The content expressed in this article is How is the hplc vials filtered? please feel free to contact me. Inject the needle into the syringe chain, then remove the filter head (0.45, 0.25um) from the needle sleeve and discard the 4, 5 drops of the initial filtrate to remove the filtrate; Micro-injectors can also be put on, are the injection heads not all uniform? If it is not possible to seal with a sealing film. The above content is How is the hplc vials filtered? I hope it will help you!
2018 12/06
-
How much is Shimazu GC vials?
The content expressed in this article is How much is Shimazu GC vials? please feel free to contact me. You can view it online, and you can view the consultation on the page: medical pharmaceutical bottle produced by Le Platinum Technology, 9mm short thread sample bottle, hplc vials,autosampler vials,8-425 thread sample bottle,Chromatography vials, gas pressure jaw head bottle, 2mL jaw head bottle, 4 -60mL storage bottle, threaded headspace bottle! The above content is How much is Shimazu GC vials? I hope it will help you!
2018 12/06
-
Some introductions about 2ml Crimp Vial
The content expressed in this article is Some introductions about 2ml Crimp Vial please feel free to contact me. The injection bottle and 2ml Crimp Vial are the most basic tools for the experimental process, especially the chromatographic experiment process. However, it is difficult to find some valuable information about the sample bottle on the Internet - except for promotional materials and advertisements. Let me talk about the importance of the 2ml Crimp Vial during the experiment: Although the autosampler seems to be insignificant compared to many sophisticated analytical instruments used in the laboratory, the incorrect use of the vial or cap or pad can have a significant impact on the experiment, resulting in experimental efficiency and repeatability. Reduced. Potential problems with incorrect use of vials/caps/slits include: Loss of analyte due to volatilization Chromatographic peaks produced by solvent and septum Mechanical damage to the autosampler Injectability is poor, etc. The poor quality of the glass is mainly poor in water resistance and acid and alkali resistance. When the long-term storage is required, the difference between the good and bad of the glass comes out. When the poor glass is stored for a long time, the inner wall will fall off and interfere with the sample. . Let's talk about the material of the 2ml Crimp Vial: Most of the vials are made of glass. When talking about this material, we must first talk about the linear expansion coefficient, which means that the temperature changes every one degree of temperature change. In short, it is the ability of glass to withstand extreme temperature changes. The lower the coefficient of linear expansion, the greater the temperature change that the glass can withstand. The classification of laboratory glass is based on USP (United States Pharmacopoeia) based on its water resistance. USP Type 1, Class A, 33 Borosilicate glass is the most chemically inert glass and is widely used in laboratories, especially for chromatographic applications. Class I glass consists mainly of silicon and oxygen and contains traces of boron and sodium. It has the lowest dissolution rate and a linear expansion coefficient of 33. USP Type 1, Class B, 51 Borosilicate glass is mainly composed of silicon and oxygen. It contains trace amounts of boron, sodium and alkali metals with a higher content than grade A glass, but it can still be used for laboratory purposes. All brown glass is Class B glass with a linear expansion coefficient of 51. Silanized or deactivated glass is a deactivated borosilicate glass that is organosilylated on the surface of the glass. The glass surface is highly hydrophobic and inert, suitable for pH sensitive compounds, trace analysis and Long-term sample storage. USP Types II, III and NP soda lime glass are less chemically resistant than borosilicate glass. In addition to the glass material, there are some other materials: Polypropylene (PP) is a hard material that can be processed into a variety of colors and has good chemical resistance, suitable for short-term storage of most laboratory chemicals. The tolerance is attenuated over time when aromatic hydrocarbons or halogenated hydrocarbons are used. PP vials are commonly used for ion chromatography due to their low ion content and can be washed with dilute acid and deionized water. The PP vial also reduces the exposure of hazardous materials as it can be directly incinerated after sealing. Polymethylpentene (TPX) is a hard, transparent material with a high melting point and a range of 0°-170°C. Due to its high transparency, TPX vials can replace opaque PP. Its chemical resistance is similar to PP, and TPX vials are typically used where visual samples or high temperature applications are required. The TPX vials are brittle at room temperature. The above content is Some introductions about 2ml Crimp Vial I hope it will help you!
2018 12/05
-
How much liquid does a 20ML Screw Top Headspace VialS contain?
The content expressed in this article is How much liquid does a 20ML Screw Top Headspace VialS contain? please feel free to contact me. Usually meet the injection volume, usually 1-1.5ml, as long as it is not full, leave a small amount of air. Once it is full, a vacuum will form during sampling and the injection volume will be inaccurate, so a small amount of air must be left. The above content is How much liquid does a 20ML Screw Top Headspace VialS contain? I hope it will help you!
2018 12/05
-
Where is the 300ul injection bottle intubation?
The content expressed in this article is Where is the 300ul injection bottle intubation? please feel free to contact me. Quzhou Laibo Technology Co., Ltd. produces complete series of consumables for gas chromatography, high performance liquid chromatography and headspace analysis. Such as: 2mL jaw head bottle, 4-60mL storage bottle, gas phase jaw head bottle, 9mm short thread sample bottle, 8-425 thread sample bottle, threaded head bottle and other models of autosampler, chromatographic sample Bottles, septa, filters, glanders, chromatography filters and other accessories, such as professional production and processing companies, have a complete, scientific quality management system, welcome everyone to visit, guidance and business negotiations. The above content is Where is the 300ul injection bottle intubation? I hope it will help you!
2018 12/05
-
I want to test the water quality. What container should I use?
The content expressed in this article is I want to test the water quality. What container should I use? please feel free to contact me. Generally use a clean and pure water bottle (do not use a bottle), you can wash the bottle several times with water before taking the water sample. According to the different requirements of the items you need to monitor, you can first consult the bottle you use to test the bottle, how much. Quzhou Laibo Technology Co., Ltd. produces complete series of consumables for gas chromatography, high performance liquid chromatography and headspace analysis. Such as: 2mL jaw head bottle, 4-60mL storage bottle, gas phase jaw head bottle, 9mm short thread sample bottle, 8-425 thread sample bottle, threaded head bottle and other models of autosampler, chromatographic sample Bottles, septa, filters, glanders, chromatography filters and other accessories, such as professional production and processing companies, have a complete, scientific quality management system, welcome everyone to visit, guidance and business negotiations. The above content is I want to test the water quality. What container should I use? I hope it will help you!
2018 12/04
-
What solvent is selected for the liquid phase injection bottle and the pipette tip?
The content expressed in this article is What solvent is selected for the liquid phase injection bottle and the pipette tip? please feel free to contact me. Answer: You can't use organic, we usually buy special cleaning solution! The above content is What solvent is selected for the liquid phase injection bottle and the pipette tip? I hope it will help you!
2018 12/04
-
What kind of experimental drugs are suitable for resorrel bottles and jars?
The content expressed in this article is What kind of experimental drugs are suitable for resorrel bottles and jars? please feel free to contact me. A fine mouth bottle for dispensing liquid reagents with a small bottle opening and a cap or stopper The jar is used to store solid reagents. Above the bottleneck is frosted glass with cap or stopper. 1. Holding solid drugs 2. As a scrubber 3. As a reaction device for solid and liquid 4. For gas metering device The above content is What kind of experimental drugs are suitable for resorrel bottles and jars? I hope it will help you!
2018 12/04
-
Why does the solution become cloudy after ultrasonic cleaning of the brown sample bottle?
The content expressed in this article is Why does the solution become cloudy after ultrasonic cleaning of the brown sample bottle? please feel free to contact me. Answer: This situation usually indicates that there are a lot of dirty things inside. The above content is Why does the solution become cloudy after ultrasonic cleaning of the brown sample bottle? I hope it will help you!
2018 12/04
-
Glass jars can't be opened for a long time
The content expressed in this article is Glass jars can't be opened for a long time please feel free to contact me. You can use hot water to heat it up, or hold the bottle with your left hand, grasp the bottle cap with your right hand, shake the bottle cap, you can! The above content is Glass jars can't be opened for a long time I hope it will help you!
2018 12/04
-
Introduction to 4ml chromatography vial / injection vial / chromatography bottle
The content expressed in this article is Introduction to 4ml chromatography vial / injection vial / chromatography bottle please feel free to contact me. Product Name: 4ml threaded brown sample bottle Brand: Qu zhou Lai Platinum Technology - CLS Product specifications: 4ml Color: brown Packing: inner packaging shrink plastic box, outer packaging carton, 100 / box Product introduction: The4ml threaded brown sample bottle can be divided into two types according to different materials. One is domestic borosilicate and the other is imported first grade hydrolyzed glass, which can meet different levels of customer demand. Standard GC, HPLC vials, small diameter 4ml threaded brown injection bottle instructions: 4ml Threaded Brown Sample Bottle - for: Agilent Agilent, Waters Waters, Beckman Beckman, Varian Varian, Shimadzu Shimadzu, Dione?x Dion, Finnigen Finigan, Gilson Gilson, LKB, Thermo Thermo And the automatic sampler of domestic chromatographic instruments. The above content is Introduction to 4ml chromatography vial / injection vial / chromatography bottle I hope it will help you!
2018 12/04
-
Advantages and disadvantages of the use of Chemical Vials (vials) for rapid washing cartridges
The content expressed in this article is Advantages and disadvantages of the use of Chemical Vials (vials) for rapid washing cartridges please feel free to contact me. The shortcomings and advantages of this product are reviewed from the perspective of users and me. Let me talk about the advantages first: 1 This washing procedure can indeed wash the Chemical Vials. After washing, the bottle looks really cleaner than the previously washed bottle. Shimadzu HPLC, GC and Agilent HPLC-MS The peaks in the previous solution were not seen on the /MS instrument. 2 It does save a lot of washing time. I used to wash 300 injection bottles in a day. Now 400 injection bottles are finished in 1.5 hours. According to the procedure designed by the inventor, the organic solvent and water are also used. Save a lot, I remember the cardboard instructions said that the total consumption of three organic solvents is not more than 2L, the total consumption of pure water is not more than 25L, the consumption should be an approximate number, but it should be almost the same. Let's focus on the shortcomings below: 1 The washing program designed in the instruction manual is too ideal. It is generally difficult for the laboratory to accumulate 400 sample bottles to be washed, unless the laboratory of the Ministry of Agriculture's pesticide residue certification like us sometimes needs more than 200 injections a day. Bottle, my other classmates used more than 100 a week is not bad. 2 Washing process I don't think it is necessary to wash the 400 sample bottles in batches. The inventor's successive washing design is not wrong to save solvent and save time, but he needs to know that the washing habits of the laboratory are very different, for example, we The laboratory organic washing solvent is washed by the organic solvent used for recycling. These solvents directly dump the waste liquid tank directly into the waste liquid tank. It is indifferent to use more than one use at a time, and there are many laboratories in my class. After washing two or three times directly with soapy water, it is enough to rinse it seven or eight times with water, not to mention the solvent saved. I think I put 200 pieces together (2 injection bottle washing boxes) into a large box, and the big box is ultrasonically washed in the ultrasonic wave, so that the ultrasonic time can be set at will. When I use the organic solvent for the second wash, I can change it into another big box. In doing so, I can buy half of the product, that is, two large boxes and two small boxes, which saves the general purchase cost. 3 Glass Liutong I don`t think it is necessary to buy or not. Why? The inventor said that taking this glass six-way can save a lot of time, 20 seconds can fill 100 injection bottles, the wrong is not wrong, I actually found that 20 seconds can fill 100, 30 seconds in the process of washing the bottle I can wash it again, but during my washing process, I also found that I can directly use the water outlet of the pure water machine to directly fill the water for 1 min, that is, I can wash it in 60 seconds without using the glass. 4 Oh, the biggest drawback is that things are too expensive, these bad boxes actually want me hundreds of oceans, I am so sad. Today, I saw that MD has risen again, and it`s really irritating. It is recommended that you buy half a set, and you must bargain when you arrive. The above content is Advantages and disadvantages of the use of Chemical Vials (vials) for rapid washing cartridges I hope it will help you!
2018 12/04

